This is a fictional demo by Fold Digital. Not for real gas work. How this demo works

User guides / C35

Norvane C35 homeowner user guide

Everything here is safe for you to do yourself. Nothing in this guide needs the boiler case to be opened.

If you smell gas: leave the property and call the National Gas Emergency Service on 0800 111 999.

Controls

The control panel is behind the drop-down flap on the front of the boiler.

DisplayShows the heating flow temperature when running, the system pressure when idle, and a fault code beginning with F if something needs attention.
Heating dial (radiator symbol)Sets the temperature of the water sent to your radiators, from 30 °C to 80 °C. Around 60 °C to 65 °C suits most homes and keeps the boiler condensing efficiently.
Hot water dial (tap symbol)Sets the hot water temperature at the tap, from 40 °C to 60 °C. We suggest 50 °C.
Mode buttonCycles between Winter (heating and hot water), Summer (hot water only) and Standby (frost protection only).
Reset buttonPress and hold for 3 seconds to restart the boiler after a lockout.

Topping up the pressure

Normal range: 1.0 to 1.5 bar when the heating is cold

  1. Switch the heating off and let the system cool for at least an hour.
  2. Read the pressure on the display. If it is below 1.0 bar, the system needs topping up.
  3. Find the grey filling lever underneath the boiler, on the left-hand side.
  4. Pull the lever down slowly. You will hear water entering the system.
  5. Watch the display and release the lever when the pressure reaches 1.3 bar. Do not go above 1.5 bar.
  6. Check the lever has sprung back fully, then switch the heating on again.
If you need to top up more than twice a year, or the pressure climbs above 2.5 bar when the heating is hot, ask a registered engineer to check the system.

Resetting the boiler

  1. Note the fault code on the display before you do anything.
  2. Press and hold the Reset button for 3 seconds, then release.
  3. Wait up to 2 minutes while the boiler runs its start-up checks.

You can reset up to 3 times in any 15 minutes. If the fault returns, stop and call a registered engineer. Repeated resets will not fix the cause.

If you smell gas, do not reset the boiler. Leave the property and call the National Gas Emergency Service on 0800 111 999.

Frost protection

Frost protection works in every mode, including Standby, as long as the gas and electricity are on.

Annual service

Your 12-year warranty depends on a service by a registered engineer every 12 months. The spanner symbol on the display lights up 11 months after the last service as a reminder.

Everyday tips

Seeing a code on the display? Look up C35 fault codes.