Fault codes
Find the code on your boiler's display. Each one tells you what it means, the one safe thing to try, and when to call an engineer.
Low system water pressure
Boiler stops until pressure is restored. Applies to: C24, C30, C35, S25, H30 Hybrid.
What it means
The water pressure in your heating system has dropped below 0.5 bar, so the boiler has stopped to protect itself.
The one safe thing to try
Top the system up to 1.3 bar using the grey filling lever under the boiler, following the steps in your user guide, then press Reset.
When to call an engineer
Call an engineer if the pressure drops again within a few weeks, if you can see a leak, or if water is dripping from the copper pipe outside.
Overheat lockout
Lockout, manual reset. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The boiler got hotter than it should, usually because water is not circulating properly, and has shut down for safety.
The one safe thing to try
Make sure at least two radiator valves are fully open, wait 30 minutes for the boiler to cool, then press Reset once.
When to call an engineer
Call an engineer if the code returns, or if the boiler is making banging or kettling noises.
Flow temperature sensor fault
Boiler stops, resets itself once repaired. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The sensor that measures the temperature of water leaving the boiler is giving a reading the boiler cannot trust.
The one safe thing to try
Switch the boiler off at the wall switch for 30 seconds, switch it back on, and press Reset once.
When to call an engineer
Call an engineer if the code comes straight back. The sensor or its wiring needs testing.
Return temperature sensor fault
Boiler stops, resets itself once repaired. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The sensor that measures the temperature of water coming back to the boiler is giving a reading the boiler cannot trust.
The one safe thing to try
Switch the boiler off at the wall switch for 30 seconds, switch it back on, and press Reset once.
When to call an engineer
Call an engineer if the code comes straight back.
Hot water temperature sensor fault
Heating continues, hot water may run cool or fluctuate. Applies to: C24, C30, C35, H30 Hybrid.
What it means
The sensor that controls your hot water temperature has a fault. Your heating should keep working, but hot water may be cooler than usual.
The one safe thing to try
Turn the hot water dial to its midpoint and run a hot tap for a minute. If the water is warm and steady, you can keep using it until an engineer visits.
When to call an engineer
Call an engineer to replace the sensor. It is not urgent unless you have no hot water at all.
Flame lost during operation
Lockout after 3 automatic restarts. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The boiler lit but the flame went out while it was running. It tries again by itself three times before stopping.
The one safe thing to try
Check that other gas appliances, such as a hob, are working and that a prepayment meter has credit. Then press Reset once.
When to call an engineer
Call an engineer if the code returns. Do not keep resetting.
Fan fault
Lockout, manual reset. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The fan that pushes air through the boiler and out of the flue is not running at the speed the boiler expects.
The one safe thing to try
Check outside that the flue terminal is not blocked by leaves, snow or a nest. If it is clear, press Reset once.
When to call an engineer
Call an engineer if the code returns. Never try to clear a blockage from inside the flue yourself.
Flue or air supply restriction
Lockout, manual reset. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The boiler has detected that air is not flowing freely through the flue, so it has stopped as a precaution.
The one safe thing to try
Look at the flue terminal outside from a safe place on the ground. Remove anything obviously covering it, then press Reset once.
When to call an engineer
Call an engineer if you cannot see a blockage, if the terminal is out of reach, or if the code returns.
Condensate blocked or frozen
Lockout, manual reset. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The pipe that drains waste water from the boiler is blocked. In cold weather this usually means the section outside has frozen.
The one safe thing to try
If it is freezing outside, pour warm (not boiling) water over the white plastic pipe where it runs outdoors, or hold a hot water bottle against it. Then press Reset.
When to call an engineer
Call an engineer if the pipe is not frozen, if you cannot reach it safely, or if the code returns once the weather warms up.
Ignition failure
Lockout after 5 ignition attempts. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The boiler tried to light five times and could not. This is often a gas supply problem rather than a fault with the boiler itself.
The one safe thing to try
Check that your gas supply is on: see whether another gas appliance works, and whether a prepayment meter has credit. If gas is available, press Reset once.
When to call an engineer
Call an engineer if the boiler does not light after one reset. Do not attempt any work on the gas valve or burner yourself. That work must only be done by a qualified, registered engineer.
No water circulation
Lockout after 3 attempts. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The boiler cannot move water around the heating system, so it has stopped to avoid overheating.
The one safe thing to try
Check that the radiator valves are open and that the pressure is at least 1.0 bar (not applicable on the R18). Then press Reset once.
When to call an engineer
Call an engineer if the code returns or radiators stay cold.
Gas valve drive fault
Lockout, manual reset. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The boiler's electronics have detected a problem with the circuit that opens the gas valve, and have shut the boiler down safely.
The one safe thing to try
Switch the boiler off at the wall switch for 30 seconds, switch it back on, and press Reset once.
When to call an engineer
Call an engineer if the code returns. This fault needs a qualified, registered engineer and is not something to investigate yourself.
Control board fault
Lockout, manual reset. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The boiler's main electronic control has found an internal error.
The one safe thing to try
Switch the boiler off at the wall switch for a full minute, then switch it back on. This clears most one-off electronic glitches.
When to call an engineer
Call an engineer if the code returns after the power has been switched off and on.
Lost contact with controls
Boiler runs at a fixed safe setting. Applies to: C24, C30, C35, S25, R18, H30 Hybrid.
What it means
The boiler has lost contact with its room control or outdoor weather sensor. It will keep your home warm at a fixed setting until this is fixed.
The one safe thing to try
If you have a wireless Norvane room control, replace its batteries and hold it near the boiler for a minute to reconnect.
When to call an engineer
Call an engineer if the code is still showing an hour after changing the batteries, or if your controls are wired.
Registered engineers can get the full diagnostic through the Norvane engineer connector or portal. Engineer portal.