User guides / R18
Norvane R18 homeowner user guide
Everything here is safe for you to do yourself. Nothing in this guide needs the boiler case to be opened.
If you smell gas: leave the property and call the National Gas Emergency Service on 0800 111 999.
Controls
The control panel is behind the drop-down flap on the front of the boiler.
| Display | Shows the heating flow temperature when running, the system pressure when idle, and a fault code beginning with F if something needs attention. |
|---|---|
| Heating dial (radiator symbol) | Sets the temperature of the water sent to your radiators, from 30 °C to 80 °C. Around 60 °C to 65 °C suits most homes and keeps the boiler condensing efficiently. |
| Hot water | Hot water temperature is set on your cylinder thermostat, not on the boiler. Keep the cylinder at 60 °C. |
| Mode button | Cycles between Winter (heating and hot water), Summer (hot water only) and Standby (frost protection only). |
| Reset button | Press and hold for 3 seconds to restart the boiler after a lockout. |
Topping up the pressure
Normal range: Not applicable. The R18 works on an open-vented system.
- Your system is filled automatically from the small feed and expansion tank in the loft, so there is no pressure to top up.
- If radiators are cold at the top, bleed them with a radiator key and the tank will refill the system on its own.
- If the system keeps needing to be bled, ask a registered engineer to check the feed tank and ball valve.
Do not fit a filling loop to this boiler. It is not designed for a sealed system unless an engineer has installed the sealed system kit.
Resetting the boiler
- Note the fault code on the display before you do anything.
- Press and hold the Reset button for 3 seconds, then release.
- Wait up to 2 minutes while the boiler runs its start-up checks.
You can reset up to 3 times in any 15 minutes. If the fault returns, stop and call a registered engineer. Repeated resets will not fix the cause.
If you smell gas, do not reset the boiler. Leave the property and call the National Gas Emergency Service on 0800 111 999.
Frost protection
Frost protection works in every mode, including Standby, as long as the gas and electricity are on.
- If the water inside the boiler drops below 5 °C, the pump and burner run until it reaches 15 °C.
- This protects the boiler itself, not the whole house. Leave the room thermostat at 12 °C or higher if you are away in winter.
- The condensate pipe can freeze in very cold weather. If it does, the display shows F25. See the fault code page for the safe way to thaw it.
Annual service
Your 7-year warranty depends on a service by a registered engineer every 12 months. The spanner symbol on the display lights up 11 months after the last service as a reminder.
- The visit takes about 45 minutes.
- The engineer checks combustion, safety devices, the flue and the condensate trap, and records the visit in your service log.
- Keep the service log safe. You will need it if you ever make a warranty claim.
Everyday tips
- Bleed radiators once a year, before the heating season.
- Keep the area around the boiler clear and never block air vents or the flue terminal outside.
- A lower heating dial setting with longer running times is usually cheaper than short bursts at high temperature.
Seeing a code on the display? Look up R18 fault codes.